Energy management
Hotel energy management: measure to decide better.
Energy is one of a hotel’s largest operating costs. We make consumption visible, understandable and controllable, based on the data and equipment actually available.
Discuss my projectLevers
From measurement to optimisation.
A gradual approach: first understand, then act, then fine-tune over time.
Metering
Using existing meters and, where needed, adding targeted sub-metering.
Energy dashboards
Indicators readable by management and technical staff alike.
Analysis by zone or use
Rooms, common areas, restaurant, wellness: understand where energy goes.
Time schedules
Run equipment according to the real opening hours of each space.
Temperature management
Consistent setpoints by zone, controlled adjustment ranges in rooms.
Occupancy-based scenes
Lower setpoints in vacant rooms, when occupancy information is available.
Fault alerts
Flagging some drifts: window open while heating, abnormal setpoint, equipment running out of hours.
Gradual optimisation
Fine-tuning settings over time, based on measured data.
Our position
Savings, without figures we can’t back up.
Energy savings depend on the building, the condition of the equipment, its use and occupancy. Announcing a percentage before any study would make no sense.
We prefer a measured approach: establish a baseline, implement the relevant actions, then observe the results in the data collected.
French regulations
Building automation and tertiary-sector obligations.
Hotels are tertiary-sector buildings in France. Two schemes may apply, depending on their floor area and the power of their installations:
- BACS decree (building automation and control systems): required for existing buildings above 290 kW since 1 January 2025, and between 70 and 290 kW by 1 January 2030 (Decree No. 2025-1343). New buildings and replaced systems above 70 kW are covered from the outset. Heating and cooling are assessed separately and are not added together, but all heating equipment in a building is added up, and likewise all cooling equipment. An exemption is possible if the payback period exceeds 10 years.
- Éco Énergie Tertiaire: from 1,000 m² of tertiary floor area, annual consumption reporting on the OPERAT platform and reduction targets of −40% by 2030, −50% by 2040 and −60% by 2050 (or an absolute threshold).
No supervision system — ours included — automatically guarantees regulatory compliance. Compliance depends on the functions actually implemented and on the required inspections. Information checked on 30 October 2026; please refer to the official French texts for any update.
Project assessment
Understand your consumption.
Share your property’s characteristics: we will identify the data available and the relevant levers.